Generating sets
INDUSTRIAL DIESEL GENERATING SETS
All gensets based on: four stroke, diesel engines with 1500 RPM by "DEUTZ" and "VOLVO Penta"
production; "STAMFORD"(ST), "MECC Alte"(ME), "Marelli"(MA), "SINCRO"(SI) alternators. All
alternators are three phase, four pole, single bearing, synchronous type, cosj=0.8, 50Hz.
| GENERAL CHARACTERISTICS |
| Model |
Rated power |
Voltage |
Alter- nator |
Diesel engine specification |
Dimensions |
Weight |
| |
kVA |
kW |
V |
|
|
LxWxH cm |
kg |
| Air cooled gensets |
| EA17DM |
17 |
13.6 |
400/230 |
SI |
"DEUTZ" F3L1011F, 3 cyl. |
160x75x90 |
380 |
| EA23DM |
23 |
18.4 |
400/230 |
SI |
"DEUTZ" F4L1011F, 4 cyl. |
160x75x91 |
500 |
| EA30DM |
30 |
24 |
400/230 |
ME |
"DEUTZ" F3L912, 3 cyl. |
175x75x120 |
700 |
| EA40DM |
30 |
32 |
400/230 |
ME |
"DEUTZ" F4L912, 4 cyl. |
200x75x120 |
750 |
| EA60DM |
60 |
48 |
400/230 |
ME |
"DEUTZ" F6L912, 6 cyl. |
225x75x120 |
850 |
| Oil cooled gensets |
| E18DM |
18 |
14.4 |
400/230 |
ST |
"DEUTZ" F3M1011F, 3 cyl. |
138x92x95 |
440 |
| E26DM |
26 |
21 |
400/230 |
ST |
"DEUTZ" F4M1011F, 4 cyl. |
150x92x95 |
590 |
| E36DM |
36 |
29 |
400/230 |
ME |
"DEUTZ" BF4M1011F, 4 cyl. |
175x92x104 |
650 |
| Water cooled gensets |
| E7DM |
7 |
5.6 |
400/230 |
ST |
"DEUTZ" F3M1008, 3 cyl. |
110x55x85 |
265 |
| E10DM |
10 |
8 |
400/230 |
ST |
"DEUTZ" F4M1008, 4 cyl. |
110x55x85 |
290 |
| E13DM |
13 |
10.4 |
400/230 |
ST |
"DEUTZ" BF4M1008, 4 cyl. |
110x60x85 |
305 |
| E50DM |
50 |
40 |
400/230 |
ME |
"DEUTZ" BF4M1012E, 4 cyl., turbocharg |
180x95x130 |
970 |
| E56DM |
56 |
45 |
400/230 |
ME |
"DEUTZ" BF4M1012E, 4 cyl., turbocharg |
180x95x130 |
1005 |
| E70DM |
70 |
56 |
400/230 |
MA |
"DEUTZ" BF4M1012EC, 4 cyl., turbocharg |
210x95x135 |
1045 |
| E85DM |
85 |
66 |
400/230 |
MA |
"DEUTZ" BF4M1013E, 4 cyl., turbocharg |
230x95x140 |
1100 |
| E100DM |
100 |
80 |
400/230 |
ME |
"DEUTZ" BF4M1013EC, 4 cyl., turbocharg |
250x95x140 |
1200 |
| E130DM |
130 |
104 |
400/230 |
ME |
"DEUTZ" BF6M1013E, 6 cyl., turbocharg |
250x95x140 |
1485 |
| E155DM |
155 |
124 |
400/230 |
ME |
"DEUTZ" BF6M1013EC, 6 cyl., turbocharg |
250x95x140 |
1610 |
| E160VM |
160 |
128 |
400/230 |
MA |
"VOLVO" TD710G, 6 cyl., turbocharg |
260x100x145 |
1300 |
| E185VM |
185 |
148 |
400/230 |
MA |
"VOLVO" TWD710G, 6 cyl., turbocharg |
250x110x185 |
1820 |
| E231VM |
231 |
185 |
400/230 |
ME |
"VOLVO" TWD1010G, 6 cyl., turbocharg |
300x110x190 |
2200 |
| E275VM |
275 |
220 |
400/230 |
MA |
"VOLVO" TWD1210G, 6 cyl., turbocharg |
300x110x192 |
2400 |
| E325VM |
325 |
260 |
400/230 |
ME |
"VOLVO" TWD1211G, 6 cyl., turbocharg |
300x110x192 |
2600 |
| E410VM |
410 |
328 |
400/230 |
MA |
"VOLVO" TWD1630G, 6 cyl., turbocharg. |
300x120x205 |
3000 |
| E505VM |
505 |
404 |
400/230 |
MA |
"VOLVO" TAD1631G, 6 cyl., turbocharg |
350x130x209 |
3500 |
| E675DM |
675 |
540 |
400/230 |
MA |
"DEUTZ" TBD616V12, 12 cyl., turbocharg |
350x140x167 |
4000 |
| E900DM |
900 |
720 |
400/230 |
MA |
"DEUTZ" TBD616V16, 16 cyl., turbocharg |
410x140x167 |
4500 |
| E1050DM |
1050 |
840 |
400/230 |
MA |
"DEUTZ" TBD620V8, 8 cyl., turbocharg |
460x144x200 |
7800 |
| STANDARD SPECIFICATIONS |
| |
Note |
| Mounting: Direct connection between the engine and alternator, mounted on steel based frame
with antivibrators, daily fuel tank built into the set1 |
All generating sets 1 - unless E675DM, E900DM, E1050DM |
| Manual control panel: Electric start ignition key, terminal box with three-phase outlet,
circuit breaker, voltmeter, three ammeters, frequency meter, hour meter, water or oil
thermometers2, oil pressure manometer, protection unit |
All generating sets 2 - unless air cooled gensets |
| Genset protection unit: provides shutdown operation and signaling in case of low oil pressure,
high engine temperature, overload by current |
|
| Parts supplied loose: silencer, battery connection wires (without battery), tool kit,
instruction manual. |
|
| Light type trailer (type 1) for cars or trucks |
E10K, E18K |
| Heavy type trailer (type 2) for trucks |
1E10K, 1E18K, 1E24CK, 1E30CK |
OPTIONAL EQUIPMENT:
- Cold start aid device;
- Remote control panel;
- Automatic control panel: mounted on the base frame with set or separate. The panel equipped
with following elements: three ammeters, oil manometer, cooling liquid thermometer (unless air
cooled sets), battery charging current ammeter, fuel level indicator, manual/automatic/repair
operating mode switch, oil preheater switch, circuit breaker, mains / alternator switch with
contactors, RGAM - automatic control unit for genset operation. RGAM unit includes: power on,
generator on, generator under load, indication of each phase voltage, elapsed hours of operation,
current frequency, battery status, protection (shutdown) and indication of fault codes, manual
selection of generator set/mains power.
- Automatic control panel with RGAM unit equipped with serial interface RS485. This version RGAM
is able to connect with PC (or intellectual terminal) for realizing of remote control and monitoring
operations of genset.
- Battery, 12V;
- Fuel tank of high capacity (loose);
- Soundproof canopy "SILENT" type provides a sound pressure level not more 70 dB at 7 meters;
- Soundproof canopy "SUPER SILENT" type provides a sound pressure level not more 65 dB at 7 meters;
- Road trailer with one (two) torsion axle
|